Overhead Line Fault Path Indicator White Color Alarming Mode Red Flag / Flashlight

Overhead Line Fault Path Indicator White Color Alarming Mode Red Flag / Flashlight
Overhead Line Fault Path Indicator White Color Alarming Mode Red Flag / Flashlight Overhead Line Fault Path Indicator White Color Alarming Mode Red Flag / Flashlight

Large Image :  Overhead Line Fault Path Indicator White Color Alarming Mode Red Flag / Flashlight Get Best Price

Product Details:

Place of Origin: Beijing,China
Brand Name: TYHD
Certification: type test report
Model Number: TYHD-AI9

Payment & Shipping Terms:

Minimum Order Quantity: 1 set
Price: Negotiation
Packaging Details: standard export Package
Delivery Time: within 3-5 working days
Payment Terms: TT,LC,westunion
Supply Ability: 3000 sets/month
Detailed Product Description
USB/RS232 Conneting Lines: Black Solar: Organic Glass Protection,amorphous Silicon,and 30 Years Of Service Life
Material: White
High Light:

precision approach path indicator

,

electrical line locator

Safety criterion    

    Welcome to use remote transmission unit manufactured by us. Each remote terminal uint has already experienced the complete assembly, test and inspection, also the careful check and adjustment before delivery, which has been in good condition when transport.

   

Device description

    Remote terminal uint is the data acquisition and communications forwarding device for power distribution network load monitoring, fault detection and positioning system, which can be set as the practical distribution terminal device of two remote (remote signaling, telemetry) functions in the distribution automation system via terminal parameter configuration, which can also be set as the traditional distribution terminal device of remote fault positioning system.

    Remote terminal uint is to process and analyze the information from overhead indicator sent via wireless and then send the circuit load current and fault information to the main distribution network station via GSM short messages or GPRS communication. 

 

Working principle

    Remote terminal uint is to receive the circuit fault information and circuit load operation information from overhead indicator installed in the circuit via wireless for analysis and compiling and then sends the information to main distribution network station via GPRS/GSM communications, to realize the online monitoring, fault detection and positioning functions of distribution network.

 

GSM or GPRS forwarding

    GSM (short messages) and GPRS (data) are mutually the standby mode, which are used to send the substation condition, circuit load current, indicator status and fault information to main distribution network station, to ensure the reliable transmitting of distribution network fault information.

 

Remote upgrade

    The equipment program can be upgraded conveniently through master remote maintenance station.

Work mode setting

    The terminal can be in the two-remote or one-remote working mode by setting the intrinsic parameters of remote terminal uint.

Two-remote working mode: the terminal is online in real time, and the circuit load current and circuit status can be uploaded.

One-remote working mode: the terminal is online regularly; when the circuit breaks down, the terminal opens GPRS module power supply and sends the fault information to main distribution network station.

Overhead Line Fault Path Indicator White Color Alarming Mode Red Flag / Flashlight 0

The equipment cover is opened

Technical parameters

Dimension of repeater station H×W×T=388mm×366mm×368mm
Weight of repeater station 6.75kg
Applied voltage grade 7~69kV overhead line
Circuit load current 0~630A
Rated working voltage 5.5V-7.5V
Overall power consumption <0.4W
Work time in rainy weather ≥10 days
Solar panel Organic glass protection, amorphous silicon, and 30 years of service life
Power of solar panel 12W/10V
Quantity of cooperation indicators 12
GPRS module E-GSM/GPRS 900/1800 dual band
Working temperature range (lead-acid battery) -35℃~75℃
Working temperature range (lithium iron phosphate) -20℃~75℃
MTBF >5×104 h