Product Details:
Payment & Shipping Terms:
|
Material: | White | Environment Temperature: | -35℃~70℃ |
---|---|---|---|
Altitude: | <2000m | Total Indicating Time: | >2000 Hours |
High Light: | precision approach path indicator,electrical line locator |
Welcome to use remote transmission unit manufactured by us. Each remote terminal uint has already experienced the complete assembly, test and inspection, also the careful check and adjustment before delivery, which has been in good condition when transport.
Abstract
The fault indicator for overhead distribution lines is used indicating of phase-to-phase and phase-to-earth faults by determining short circuit, over-current and power features to detect faults and provide a local light indication. In addition, the indicator also has current measurement and wireless data communication capabilities, by sending the fault signal to FTU,in order to comply the function of the remote communication and the remote monitoring, to help operators to find the point of failure quickly and shorten the outage time and improve reliability.
Remote terminal uint is the data acquisition and communications forwarding device for power distribution network load monitoring, fault detection and positioning system, which can be set as the practical distribution terminal device of two remote (remote signaling, telemetry) functions in the distribution automation system via terminal parameter configuration, which can also be set as the traditional distribution terminal device of remote fault positioning system.
Main features
1. GSM or GPRS forwarding
GSM (short messages) and GPRS (data) are mutually the standby mode, which are used to send the substation condition, circuit load current, indicator status and fault information to main distribution network station, to ensure the reliable transmitting of distribution network fault information.
2. Remote upgrade
The equipment program can be upgraded conveniently through master remote maintenance station.
3. Work mode setting
The terminal can be in the two-remote or one-remote working mode by setting the intrinsic parameters of remote terminal uint.
Two-remote working mode: the terminal is online in real time, and the circuit load current and circuit status can be uploaded.
One-remote working mode: the terminal is online regularly; when the circuit breaks down, the terminal opens GPRS module power supply and sends the fault information to main distribution network station.
Functions
1. Wireless receiving: the fault point information and load current information sent by indicator are received via short-range wireless network mode.
2. GSM or GPRS forwarding: GSM (short messages) and GPRS (data) are mutually the standby mode, which are used to send the substation condition, circuit load current, indicator status and fault information to main distribution network station, to ensure the reliable transmitting of distribution network fault information.
3. Solar power supply: the solar power supply mode is applied, and the maintenance-free 8AH lead-acid battery or 12AH lithium iron phosphate battery is provided, with the working temperature range of both batteries of -35℃~75 ℃ and -20℃~75℃ separately.
4. Optional communication protocol: IEC870-5-101 protocol or 104 can be selected for the connection with the third party equipment to upload the fault and shift information.
5. Remote upgrade: the equipment program can be upgraded conveniently through master remote maintenance station.
6. Convenient maintenance: the parameter setting and equipment maintenance can be performed conveniently via wireless setting terminal.
7. Event recording: the device can record the maximum 500 pieces of SOE events, providing the rich data support for system fault analysis.
Technical parameters
Dimension of repeater station |
H×W×T=388mm×366mm×368mm |
Weight of repeater station |
6.75kg |
Applied voltage grade |
7~69kV overhead line |
Circuit load current |
0~630A |
Rated working voltage |
5.5V-7.5V |
Overall power consumption |
<0.4W |
Work time in rainy weather |
≥10 days |
Solar panel |
Organic glass protection, amorphous silicon, and 30 years of service life |
Power of solar panel |
12W/10V |
Quantity of cooperation indicators |
12 |
GPRS module |
E-GSM/GPRS 900/1800 dual band |
Working temperature range (lead-acid battery) |
-35℃~75℃ |
Working temperature range (lithium iron phosphate) |
-20℃~75℃ |
MTBF |
>5×104 h |
Fax: 86-10-63330700