Sincerity Is Fundamental, Clients Is The First.

 

Strict Quality Control, Earnest Service Supply.

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsFault Passage Indicator

1 Earth Power Supply Failure Indicator , 3 Phase Voltage Indicator For Underground Cable

I'm Online Chat Now
Certification
China Beijing Tianyihongda Science & Technology Development Co., LTD certification
China Beijing Tianyihongda Science & Technology Development Co., LTD certification
Super friendly service, the Power Line Fault Indicator high quality as expected and very economy and environmental protection.

—— Bruce

This is the first time i do Underground Cable Fault Indicator business , after i received , it is work well. and now i want to order more.

—— Joseph

1 Earth Power Supply Failure Indicator , 3 Phase Voltage Indicator For Underground Cable

1 Earth Power Supply Failure Indicator , 3 Phase Voltage Indicator For Underground Cable
1 Earth Power Supply Failure Indicator , 3 Phase Voltage Indicator For Underground Cable 1 Earth Power Supply Failure Indicator , 3 Phase Voltage Indicator For Underground Cable

Large Image :  1 Earth Power Supply Failure Indicator , 3 Phase Voltage Indicator For Underground Cable Get Best Price

Product Details:

Place of Origin: China,Beijing
Brand Name: TYHD
Certification: Type test report
Model Number: TYHD-AI10

Payment & Shipping Terms:

Minimum Order Quantity: 1 sets including 3 short-circuit indicators ,1 earth fault indicator and one panel indicator
Price: Negotiation
Packaging Details: standard export package
Delivery Time: 3-5 working days
Payment Terms: L/C, T/T, Western Union
Supply Ability: 3000 sets/month
Detailed Product Description
Type: Used For Underground Cable Functions: 1.Short-circuit Alarm IndicationEarth And Fault Alarm Indication
Reset: Manual Reset Data Transmission: Remotely Transmission
Test: Self-checking
High Light:

overhead fault indicators

,

smart sensor indicator

I. Brief Introduction

Fault Passage Indicator for short-circuit and earth fault indicator for underground cable is a set of accessory device installed in RMU, Cable Branch box and Transformer Substation of Power Distribution System, is used for monitoring and indicating short-circuit and earth fault of corresponding cable sections. When single phase earth fault and short-circuit happened, the indicating light will flash and alarm. The operator can confirm the fault type, fault area and find out fault point according to the alarm indication, which will improve the work efficiency and play a very important role on power supply reliability. We can meet clients's different requirements for different parameters.

II main functions

1. Short-circuit alarm indication

The short-circuit sensor detects line current during works, when short-circuit happened, the current reaches or overceeds a certain value of short-circuit, the sensor will send alarm signal and transmit the information to host by optical fiber, the host will generate corrsponding alarm indication signal after receiving this signal.

 

2. Earth fault alarm indication

The earthed sensor detects line zero-sequence current during works, when earth fault happened, the earthed current reaches or overceeds a certain value of earth fault, the sensor will send alarm signal and transmit the information to host by optical fiber, the host will generate corrsponding alarm indication signal after receiving this alarm signal.

3. Reset automatically:when FCI transmit alarm signals, the indicator can reset automatically by itself after a setted duration if no person to make reset.

4. Personnel reset: after indicator alarm, the alarm can be removed by touch off the button of “reset/test” on host panel of indicator.

5. Automation:when the indicator generatets corresponding alarm signal, it can output the alarm signal and remotely transmit. Indicators also can receive remote reset signal to do reset operaration.

6.Test: indicators can do self-checking works.

III Installation

1. Host install

Host can be installed in the front panel of RMU, power distriburion cabinet, Cable Branch box and Transformer Substation. The shrapnel on host case must be pressed when host being dismounted. The host size is 98×50×80 mm( width*height*thickness), hole size:92×44mm(±0.2mm)deepness:80mm

2.installation of short-circuit sensors

Short-circuit sensor must be intsalled on signle-phase branch of cables, can be directly installed on cables been tested and need to be fixed tightly to prevent slide and droped off. Installation is as diagram1, dismounting as diagram2

1 Earth Power Supply Failure Indicator , 3 Phase Voltage Indicator For Underground Cable 0

                                                                    diagram1

1 Earth Power Supply Failure Indicator , 3 Phase Voltage Indicator For Underground Cable 1

                                                                    diagram2

3.earthed sensor installation

it needs to be enclosed the three wires of cables when earthed sensor installed,

the earthed line of cable must wire back sensor and fixed tightly to preventt slide         1 Earth Power Supply Failure Indicator , 3 Phase Voltage Indicator For Underground Cable 2

and dropped off as right diagram3

4. connection:

Sensor and host is connected by optical fiber, the two ends of optical fiber inserted

to optical connectors of sensor and host respectively when installed, srew tightly the connectors and make the

optical fiber not been pulled out.

IV operation:

1. Test: when needs to be self-checked, press button of “ reset/test” on panel, the device get into self-checking state, all the indicators on panel flashing and output relay closing, which tells the working state is normal, within 6 minutes or press again button of “reset/test” can end the self-checking process and recover to normal state.

2. Clear alarm: when fault happened, indicator will send alarm signal, the alarm should be cleared after fault solved, pressing the button of “ reset/test” on host panel of indicator can clear alarm. If no person to reset, the indicator can reset automatically by itself in setted time of 8hours.

3. Remote reset: when needs to be reset remotely, the external contactor of remote reset terminal short-circuit for 2 seconds, the indicator can reset. This remote reset connector adopts relay contact method, it is in effect when contacts closed.

4. Remote signal:after indicator generating corresponding alarm signal, the alarm signal can be outputed and remotely transmitted by internal relay contact of device itself. This indicator is configured two-way remote signal, one pair of open and one pair of close contactsoutput (remote relay output capacity:DC30V—1A AC230V—0.5A), user can make ues of this signal to induce indicator’s alarm signal to controll room so as to view and quickly find out the fault area.

5. Battery change: the indicator use speciall battery, when battery is changed, turn the knob on host cover and change the specillized battery, waste battery should be took back and prevent to make invironmental pollution or accident.

V Technical Parameters

1.alarm judgement criteria

Short-circuit alarm:≥150A, error ±10%, factory set is 680A, time delay for short-circuit 100mS.

Earthed current alarm:10A~60A,error ±10%, factory set is 10A, time delay for earthed 500mS

2. Working power: ER14505A lithium battery3.6V( life is above 5 years)

3. whole device standby current ≤ 5μA

4. auto reset time::6h~48h (fatory set is 8h)

5. indicator protection degree: host IP40, sensor IP65

6. remote relay:230V/AC-0.5A 30V/DC-1A

7. short-circuit sensor max tolerant current:20KA 4S

8. working ambient:-40℃~+75℃;relaive temperature:≤95%;water proof, acid proof, salt and fog proof.

9.. applicable range:system voltage below 20kV.

VI, device list:

  • host 1set 2. short-circuit sensor 3pcs 3. Earthed sensor 1pc
  • 4. Transmit optical fiber 4 pcs/ set

 

 

Contact Details
Beijing Tianyihongda Science & Technology Development Co., LTD

Fax: 86-10-63330700

Send your inquiry directly to us