Sincerity Is Fundamental, Clients Is The First.

 

Strict Quality Control, Earnest Service Supply.

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsPower Distribution Terminal

Wireless Transmission 50HZ Power Distribution Terminal For Monitoring Fault

I'm Online Chat Now
Certification
China Beijing Tianyihongda Science & Technology Development Co., LTD certification
China Beijing Tianyihongda Science & Technology Development Co., LTD certification
Super friendly service, the Power Line Fault Indicator high quality as expected and very economy and environmental protection.

—— Bruce

This is the first time i do Underground Cable Fault Indicator business , after i received , it is work well. and now i want to order more.

—— Joseph

Wireless Transmission 50HZ Power Distribution Terminal For Monitoring Fault

Wireless Transmission 50HZ Power Distribution Terminal For Monitoring Fault
Wireless Transmission 50HZ Power Distribution Terminal For Monitoring Fault Wireless Transmission 50HZ Power Distribution Terminal For Monitoring Fault Wireless Transmission 50HZ Power Distribution Terminal For Monitoring Fault

Large Image :  Wireless Transmission 50HZ Power Distribution Terminal For Monitoring Fault Get Best Price

Product Details:

Place of Origin: Beijing,China
Brand Name: Tianyihongda
Certification: type test report
Model Number: TYHD-FTU-CB(12)

Payment & Shipping Terms:

Minimum Order Quantity: 1set(3pcs)
Price: Negotiation
Packaging Details: standard export package
Delivery Time: 1800 sets within 1 week
Payment Terms: L/C, T/T, Western Union
Supply Ability: 1800sets per week
Detailed Product Description
Input Operating Voltage Frequency: 50HZ Allowable Fluctuation Range Of Input Operating Voltage: ±20%
Insulation Impedance: >100MΩ/ DC500V;External Terminal To Ground Power Frequency Withstand Voltage: 500;On-off Input Circuit To Ground
Impulse Withstand Voltage: 1k;On-off Input Circuit To Ground Item: Power Distribution Terminal
High Light:

feeder remote terminal unit

,

dsp digital signal processor

Wireless transmission and remote control power distribution feeder terminal unit monitoring fault and data transmission

 

The device inherits the rich R&D and onsite operation experience of our company in relay protection devices, measuring and control devices, communication devices and distribution network automation. Many relevant aspects are taken into account and various technical methods are adopted. The terrible operating conditions for the device are fully taken into account in the design. The device features excellent electromagnetic compatibility, low power consumption and a wide range of operating temperature. It is shockproof, moisture-proof, lightning-proof and of great reliability and stability.

 

Wireless Transmission 50HZ Power Distribution Terminal For Monitoring Fault 0

Structure of Main Interface

Wireless Transmission 50HZ Power Distribution Terminal For Monitoring Fault 1

 

When the system is idle. The main interface displayed by the LCD in a real-time manner is as shown in the above picture. The description is as follows:

1. Protocol type: It is shown at the upper left corner of the main interface, indicating the communication protocol type used currently. No indication will be shown if the communication function is not enabled.

2. Switch status: It is shown at the left of the main interface, indicating the current status of the switch. Animation is used to simulate the opening or closing status of the switch, which is intuitional and easy to understand.

Remote metering area: It is at the right of the main interface, indicating the remote metering data collected currently. The table for remote metering symbols is as follows:

Wireless Transmission 50HZ Power Distribution Terminal For Monitoring Fault 2

Wireless Transmission 50HZ Power Distribution Terminal For Monitoring Fault 3

 

Description of Toggle Switch

There are three toggle switches on the panel of the device. The function definition varies as different switches are used. The configuration schemes of toggle switch are as follows:

 

No.

With ring network automation function Without ring network automation function
  •  
Operation: Local/Remote Operation: Local/Remote
  •  
Ring network: On/Off Unlock/Lockout
  •  
Mode: Segment/Interconnect Standby

Note: P

The functions of toggle switch are as follows:

Name Position Description
Operation Local Activate buttons on the device panel, small remote controller, PDA, serial port and other local opening or closing operations
Remote Activate mobile phone SMS, background master station and other remote opening or closing operations
  Unlock Activate device protection logic, background master station, opening or closing on the panel and other operations
Lockout Deactivate device protection logic, background master station, opening or closing on the panel and other operations
Ring network On Switch off ring network function. Only the regular overcurrent protection logic is activated.
Off Switch on ring network function
Mode Segment Switch on segmented mode of automation function
Interconnect Switch on interconnected mode of automation function

lease refer to the product for the actual configuration.

 